L900 Software
The L900 software package is our laser flash photolysis (transient absorption) acquisition and analysis software.
This fully comprehensive spectrometer software provides spectrometer control, performance monitoring, transient absorption and emission decay data, time-gated spectra acquisition and data analysis.
Product Description
A variety of different measurements and correction methods are available. For example, if the probe shutter is programmed to be closed during the measurement then normal time-resolved emission measurements can be made. If a measurement sequence is made with alternate switching between probe shutter open and probe shutter closed then the result is a measurement of transient absorption which is corrected for emission.
The data acquisition dialogue boxes allow the direct import of data captured with the digital storage oscilloscope whilst in kinetic mode. Data averaging can be made either within the oscilloscope in order to make effective use of high repetition rate sources, or the data can be transferred to the computer memory and averaged there.
At the end of a measurement sequence, the raw data is converted into optical density data.
The L900 software package offers a comprehensive library of data analysis routines, including 1- to 4-exponential and reconvolution fits, analysis of growth and decay kinetics.
The following analysis features are available in the L900 software:
- Computer-controlled operation of all excitation sources, laser shutter, probe shutter, monochromator wavelengths and monochromator spectral band width
- Full control of all relevant oscilloscope settings (LP980-K, Kinetic mode)
- Full control of all relevant ICCD settings (LP980-KS, Kinetic & Spectral mode)
- Time-resolved absorption and emission spectra using data slicing (using photomultiplier)
- Absorption and emission spectra , kinetics via data slicing (using ICCD Camera)
For a full list of features and tools of the L900 package please see the specifications tab.
Technical Specifications
Measurement Modes | Control Features | Data Manipulation and Display |
---|---|---|
Measurement setup | Wavelength / slit control | ΔOD calculation (automatic and manual) |
Single kinetic measurement: – Transient absorption – Laser-induced emission |
Grating selection | Arithmetic (+, -, x, /, append) |
Multiple kinetic measurements: – Transient absorption – Laser-induced emission |
Pump laser flashlamp trigger | Scaling |
Time-Resolved Absorption Spectra (TRAS) | Pump laser Q-switch trigger | Normalise |
Time-Resolved Emission Spectra (TRES) | Probe source pulse current | Baseline subtraction |
Stop-flow mode for use with optional stopped flow accessory | Pump and probe shutters | Smooth |
Oscilloscope trigger (K mode) | Data slicing – TRAS | |
Oscilloscope time base (K mode) | Data slicing – TRES | |
Oscilloscope voltage scale (K mode) | Full data reconvolution using non-linear least square fitting routine | |
Signal offset (K mode) | 2D, 3D, Contour plotting and text | |
Time shift / delay (K mode) | ||
ICCD gain (KS mode) | ||
ICCD gate delay and gate width (KS mode) | ||
ICCD temperature (KS mode) | ||
Optional temperature controlled sample holder | ||
Optional cryostat mounting | ||
Stop-flow synchronisation |